unless instructed to by Ross Video Technical
Support. Ensure that you have stored your option
codes before attempting to delete the options.
4. Press Backup Codes To USB/Backup Option
Codes.
To Recall Options Codes
The switcher uses the active disk type for storing and
recalling option codes. You must set the disk and then
perform the backup or recall.
1. Press HOME > Disk
2. Use the Disk Type knob to select whether you want
to use the hard drive of the switcher (Hard Drive),
or a USB drive (USB).
Note: You cannot store or recall files from the USB on the
Acuity Rack Panel server. You must store or recall the files
from the Local Disk and access it over the network. Point
your file explorer to the localdisk folder on the server
(\\##.##.##.##\localdisk). The user name
is nobody and there is no password.
3. Press HOME > Setup > Installed Options >
More.
Important: The Delete Selected SW Option
and Delete All SW Options commands allow
you to delete selected, or all, installed software
options. Do not attempt to delete your options
unless instructed to by Ross Video Technical
Support. Ensure that you have stored your option
codes before attempting to delete the options.
4. Press Recall Codes From USB/Recall Option
Codes.