Calibration
Calibration allows you to reset the limits of the faders
on the control panel, re-center the positioner with X, Y
and Z limits, and align the touchscreen display.
Calibration can also be used to have the LEDs in the
buttons of the control panel display in a calibrated, or
uncalibrated mode. When the control panel is
manufactured, the LEDs for each button are calibrated
to a single standard so that all the buttons appear as a
consistent color. This color offset is stored in each
module.
To Calibrate the Fader and Positioner
1. Press HOME > Setup > Installation > More >
Calibration > ADC Calibration.
2. Move a fader handle from one limit to the other and
back again. Be sure not to pressure the fader into the
stop. Doing so may make it difcult to end a
transition, or cause the fader to accidentally start a
new transition when it is released.
3. Move the positioner forwards and backwards, left
and right, and twist the positioner clockwise and
counter-clockwise. This calibrates the positioner in
all three directions.
4. Press Accept.
5. Press HOME > Confirm.
To Turn Button LED Calibration Off
1. Press HOME > Setup > Installation > More >
Calibration.
2. Use the LED Calibration knob to turn the
calibration of the LED buttons off (Yes), or use the
calibration offsets (No).
• Yes — the factory installed calibration offset
values are not used. The LED buttons may
appear to be slightly different colors.
• No — the factory installed calibration offset
values are used.
3. Press HOME > Confirm.
Acuity Setup Manual (v9.2) — Calibration • 93