Calibration
Calibration allows you to reset the limits of the faders
on the control panel, re-center the positioner with X, Y
and Z limits, and align the touchscreen display.
Calibration can also be used to have the LEDs in the
buttons of the control panel display in a calibrated, or
uncalibrated mode. When the control panel is
manufactured, the LEDs for each button are calibrated
to a single standard so that all the buttons appear as a
consistent color. This color offset is stored in each
module.
To Calibrate the Fader and Positioner
1. Press HOME > Setup > Installation > More >
Calibration > ADC Calibration.
2. Move a fader handle from one limit to the other and
back again. Be sure not to pressure the fader into the
stop. Doing so may make it difcult to end a
transition, or cause the fader to accidentally start a
new transition when it is released.
3. Move the positioner forwards and backwards, left
and right, and twist the positioner clockwise and
counter-clockwise. This calibrates the positioner in
all three directions.
4. Press Accept.
5. Press HOME > Confirm.
To Turn Button LED Calibration Off
1. Press HOME > Setup > Installation > More >
Calibration.
2. Use the LED Calibration knob to turn the
calibration of the LED buttons off (Yes), or use the
calibration offsets (No).
Yes the factory installed calibration offset
values are not used. The LED buttons may
appear to be slightly different colors.
No the factory installed calibration offset
values are used.
3. Press HOME > Confirm.
Acuity Setup Manual (v9.2) Calibration 93