SEEDMASTER 2023
38
ZONE COMMAND AIR COMPRESSOR
SeedMaster’s Zone Command is controlled pneumatically. To provide an air supply, the drill is equipped
with a compressor and air tank. The compressor is set to turn off when the pressure in the tank reaches
105 psi, and to turn on when the pressure falls below 85 psi. A regulator is used to reduce the tank
pressure for the air cylinders. This regulator is factory set to 65 psi.
NOTE: The air compressor will only start when the monitor is powered on. Ensure that the
compressor builds up to proper operating pressure and shuts off.
If the compressor will not shut off, inspect the air system for leaks. Increased or infinite run
times can damage and shorten the lifespan of the compressor.
NOTE: Check the air inlet filter on the compressor daily and replace as necessary. Ensure that
the air filter is dry and not dirty, or damage to the compressor will result.
AIR
FILTER
AIR
REGULATOR
Zone Command Air Compressor

Table of Contents