Service Manual 121
Installation
1. Make sure the SE-3 Patroller is powered off,
unplugged, and the parking brake is engaged.
2. Route the harness down the right side of the skid
plate. See Figure 168.
3. Connect the harness to the Rear Strobe Lights.
See Figure 167.
4. Install two cable ties connecting the harness to the
rear of the Motor Cavity.
5. Route the harness up the right side of the frame and
under the horizontal brace on the frame.
6. Connect the wire harness to the PI Board.
See Figure 166.
7. Install two cable ties around the harnesses on the
side of the frame.
8. Install the following components:
a. Motor Cavity Lid (page 89)
b. Rider Detect Mat (page 82)
c. Side Panel (page 20)
d. Light Cluster (page 18)
e. Front Cowl (page 17)
f. Electronics Shield (page 100)
g. Glove Box (page 16)
h. Bib Panel (page 14)
i. Storage Trays (page 13)
j. Battery Module (page 8)
9. Perform post-service tests (page 127).
Harnesses
Figure 168: Rear Strobe Light Harness Routing