13-11
Communication
13
(5) Corrected light level reading: code 29
(H)
The corrected light level measured by the illuminance monitor function, the evaluation result and
preset reference light level are read.
- Object type _ Object type for which the measurement was executed: 00 to 15
- Result _ 0: NG, 1: OK
- Corrected light level _ Corrected light level (±0 to 255.0)
- Reference light level _ Light level used as the criterion (0 to 255.0)
Ë Response
:29RC
(H)
RC
(L)
Corrected
light level
Reference
light level
±10
2
10
1
10
0
10
2
10
1
10
0
10
-1
10
-1
SC
(H)
SC
(L)
CR
Result
:29 SC
(H)
SC
(L)
Ë
Command
CR
Object
type
Camera No.
- Camera No. _ 1: camera 1, 2: camera 2