14-17
Computer Link
14
In the initial state, addresses #234 and #235 are set to 000.
#234
76543210
#235
D5
0
1
D4
0
0
1
D3
0
1
0
D1
0
0
1
1
0
Transmission speed (k bit/sec)
9.6
19.2
38.4
57.6
115.2
D0
1
0
1
0
1
D
2
0
0
1
1
1
* Applicable only to
the JW-32CUH1/M1 and JW-33CUH1/H2/H3
*
7 bits,
fixed
Data
Stop
1 bit
2 bits
Parity
None
Odd
Even
Station No.
(001 to 037
(8)
)
Enter the station No. for the current station.
[2] Connection with a Sharp PC
[Applicable models]
1. Control module: JW-22CU (can be used with ROM version 2.2 or later)
JW-70CUH/100CUH, JW-32CUH/H1/M1
JW-33CUH/H1/H2/H3
2. Basic module: JW-1324K/1342K/1424K/1442K/1624K/1642K
3. CPU board: Z-311J/312J
4. Link module: JW-21CM, JW-10CM
5. Communication board: Z-331J/332J
(1) Module setting
11
11
1 When a JW-22CU or a JW-70CUH/100CUH and Z-311J/312J are used
Store the communication port conditions in system memory addresses #236 and #237.
Bits D
0
to D
5
are stored in memory address #236.
In the initial state, addresses #236 and #237 are set to 000.
2 2
2 2
2 When a JW-32CUH/H1/M1 or a JW-33CUH/H1/H2/H3 is used
1. When communication port 1 (PG/COMM1 port) is used
Store the communication conditions in system memory addresses #234 and #235. Set bits D
0
to
D
5
in memory address #234. Only an RS-422 cable can be connected to the PG/COMM1 port.
#236
76543210
#237
Station No.
(001 to 037
(8)
)
Enter the station No. for the current station.
7 bits,
fixed
Data
D
5
0
1
Stop
1 bit
2 bits
D
4
0
0
1
Parity
None
Odd
Even
D
3
0
1
0
D
1
0
0
Transmission speed (k bit/sec)
9.6
19.2
D
0
1
0
D
2
0
0

Table of Contents