3-48
3
Operation Examples (Numeric calculation)
2
2
4
3
4
5
6
[RESULTS OUTPUT]

TYPE(00)
1PAGE NO.

0(0~7) REG.NO YES
2SET POSITION MOVE
3INPUT SIGNAL AUXRLY C000(0~127) EXT-INP X0(0~6)
TMR TM0(0~7) CNT CN0(0~7)
AN00(0~15) OUT Y00(0~15)
4LOGICAL SYMBOL
5OUTPUT SIGNAL OUTY00(0~15) AUXRLY C 000(0~127)
TMR TM0(0~7) SET-VL000(000~999)
CNT CN0(0~7) SET-VL 000(000~999)
DEL.
6UPPER MENU
[PAGE 0]
INPUT0
LOGIC
INPUT1
LOGIC
INPUT2
LOGIC
INPUT3
LOGIC
10 234567OUT
DEL.
C000
01234567OUT
[PAGE0]
INPUT0
LOGIC
[PAGE0]
INPUT0
LOGIC
C000
01234567OUT
Y00
Continued from the preceding page
(4) Operation for item, r RESULTS OUTPUT (final output conditions), on the [OBJECT TYPE COND]
menu
1. On the [OBJECT TYPE COND] menu, move the cursor to r RESULTS OUTPUT with the up
and down keys, and press the SET key.
- The RESULTS OUTPUT (final evaluation output condition) menu will be displayed.
2. Move the cursor to 1 PAGE NO. with the up and down keys, and press the SET key. Move
the cursor to "YES" with the left and right keys, and press the SET key.
- Items 2 to 5 will be displayed.
3. Move the cursor to 2 SET POSITION with the up and down keys, and press the SET key.
- Move the cursor to the 0th column of INPUT 0 for logic setting using the up, down, left and
right keys, and press the SET key.
4. Move the cursor to 3 INPUT SIGNAL with the up and down keys, and press the SET key.
- Move the cursor to AUXRLY C000 (0 ~ 127) (auxiliary relay C000) with the left and right
keys, specify C000 with the up and down keys, and press the SET key.
- The logic symbol will be displayed in the 0th column of INPUT 0.
5. Move the cursor to 5 OUTPUT SIGNAL with the up and down keys, and press the SET key.
- Select "OUTY00(0 to 15)" with the left and right keys, enter "00" with the up and down keys,
and press the SET key.
- The output coil for INPUT 0 will be displayed.
6. Move the cursor to 6 UPPER MENU with the up and down keys, and press the SET key.
- The screen will return to the [OBJECT TYPE COND] menu.
Continued on the following page

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sharp IV-S20 and is the answer not in the manual?

Sharp IV-S20 Specifications

General IconGeneral
BrandSharp
ModelIV-S20
CategoryColor Camera
LanguageEnglish