93
No
Abbr.
Function description
Control
mode
Setting
range
Unit
PC01
STA
Acceleration time constant
This parameter is the time spent for the motor from 0 rpm to the
rated speed and it is defined as acceleration time constant.
Pr
S,T
0
~20000
ms
PC02
STB
Deceleration time constant
The time spent for the motor to decelerate from the rated speed
to 0 rpm is called deceleration time constant.
Pr
S,T
0
~20000
ms
PC03
STC
S-pattern acceleration/deceleration time constant
The S-pattern acceleration/deceleration function is to employ a
three-step curve of acceleration or deceleration moving to
soothe the vibration during starting or stopping the motor.
Pr
S,T
0
~10000
ms
PC04
JOG
JOG speed command
As JOG mode applied, this PC04 is used as speed command.
Pt, Pr
S,T
0
~4500
rpm
PC05
SC1
Inner speed command/limit 1
For speed control, PC05 is used as inner speed command 1.
For torque control, PC05 is the speed limit and directionless.
S,T
-4500
~+4500
rpm
PC06
SC2
Inner speed command/limit 2
For speed control, PC06 is used as inner speed command 2.
For torque control, PC06 is the speed limit and directionless.
S,T
-4500
~+4500
rpm
PC07
SC3
Inner speed command/limit 3
For speed control, PC07 is used as inner speed command 3.
For torque control, PC07 is the speed limit and directionless.
S,T
-4500
~+4500
rpm
PC08
SC4
Inner speed command/limit 4
For speed control, PC08 is used as inner speed command 4.
For torque control, PC08 is the speed limit and directionless.
S,T
-4500
~+4500
rpm
PC09
SC5
Inner speed command/limit 5
For speed control, PC09 is used as inner speed command 5.
For torque control, PC09 is the speed limit and directionless.
S,T
-4500
~+4500
rpm
PC10
SC6
Inner speed command/limit 6
For speed control, PC10 is used as inner speed command 6.
For torque control, PC10 is the speed limit and directionless.
S,T
-4500
~+4500
rpm
PC11
SC7
Inner speed command/limit 7
For speed control, PC11 is used as inner speed command 7.
For torque control, PC11 is the speed limit and directionless.
S,T
-4500
~+4500
rpm

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SDE-100A2 and is the answer not in the manual?

Shihlin electric SDE-100A2 Specifications

General IconGeneral
BrandShihlin electric
ModelSDE-100A2
CategoryDC Drives
LanguageEnglish

Related product manuals