168
JUMP : TYPE=7, it is used to jump to the assigned PR.
Bit
31~28
27~24
23~20
19~16
15~12
11~8
7~4
3~0
PE03
X
X
DLY
X
Acc. / Dec.
OPT
7
PE04
PATH#: The assigned PRx, x=0~63
OPT setting:
OPT
Bit 7
Bit 6
Bit 5
Bit 4
X
X
X
INS
1
0
INS=1: It indicates that the current PR would immediately replace the previous PR.
WRITE : TYPE=8, write the assigned PR to the specific parameter
Bit
31~28
27~24
23~20
19~16
15~12
11~8
7~4
3~0
PE03
X
SOUR
DLY
Destination parameters
OPT
7
PE04
Source (constant or parameter number)
OPT setting:
OPT
Bit 7
Bit 6
Bit 5
Bit 4
X
ROM
AUTO
INS
1
0
1
0
1
0
INS=1: It indicates that the current PR would immediately replace the previous PR.
AUTO=1: When the current PR is done, the next PR would be executed automatically.
ROM=0: The relevant parameter modification is not saved into EEPROM.
ROM=1: The relevant parameter modification will be saved into EEPROM.
Destination parameters setting: Parameter group and number could be assigned.
OPT
Bit 19~16
Bit 15~12
Bit 11~8
Group
A1
B2
C3
D4
E5
F6
Parameter No.
P0505
P4545
P9898
P7777
Parameter
Parameter

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Shihlin electric SDE-100A2 and is the answer not in the manual?

Shihlin electric SDE-100A2 Specifications

General IconGeneral
BrandShihlin electric
ModelSDE-100A2
CategoryDC Drives
LanguageEnglish

Related product manuals