OPERATING INSTRUCTIONS | Bulkscan LMS511 8014829/ZNC5/2017-06-06 | SICK
Subject to change without notice
40
ELECTRICAL INSTALLATION
Other connection cables may have different wire colors.
Encoder input 1 is connected to encoder output A (0°).
Encoder input 2 is connected to encoder output B (90°).
6.2.3 Ethernet interface connection
2
3
Fig. 19: Pin assignment of the "Ethernet" connection (M12×4 socket, D coded)
Pin Signal Function
1 TX+ Transmit+
2 Rx+ Receive +
3 TX- Transmit -
4 Rx- Receive -
Tab. 7: Pin assignment of the "Ethernet" connection
Pre-assembled connection cables are available as accessories (see "12.2 Accessories“
on page 77).
Other connection cables may have different wire colors.
6.2.4 Serial interface connection
Fig. 20: Pin assignment of the "Data" connection (M12×12 plug, A coded)
Pin Wire color Signal Function
1 Brown 24 V EXT Power supply digital outputs 1 + 2
2 Blue RD–/RxD RS-422/485/RS-232
3 White OUT1 Digital output
1 )
4 Green GND RS GND serial data
5 Pink OUT2 Digital output 2
1)
6 Yellow Reserved Do not use
7 Black TD–/TxD RS-422/485/RS-232
8 Gray Reserved Do not use
9 Red RD+ RS-422/485
10 Violet TD+ RS-422/485
11 Gray/pink Reserved Do not use
12 Red/blue Reserved Do not use
Tab. 8: Pin assignment of the "Data" connection
Note