OPERATING INSTRUCTIONS | Bulkscan LMS511 8014829/ZNC5/2017-06-06 | SICK
Subject to change without notice
90
APPENDIX
13.1.13 Service data
Permissible commands: sRN, sEN
Variable name Description Variable type Value range Unit
ODpwrc
Operating data: Power up
counter
uint_32
OPcurtmpdev
Device status: Current tem-
perature
oat_32 °C
SCdevicestate
Device status: Operational
status
uint_8 0: Busy
1: Ready
2: Error
LCMstate
Device status: Contamina-
tion
uint_8 0: No contami-
nation
1: Warning
2: Contaminat-
ed
3: Fail
ODoprh
Operating data: Operating
hours
uint_32 0 ... 4 x 10
9
1/10 h
ODopdaily
Operating data: Daily oper-
ating hours
oat_32 0 … 4 x 10
8
1 h
DIuser
Service information: Last
user
string (max. 18
characters)
DIpara
Service information: Last
conguration
string DD.MM.YYYY Date
DIparatm
HH:MM Time
Permissible commands: sRN, sWN
Variable name Description Variable type Value range Unit
DIlstmt
Service information: Last
maintenance
string DD.MM.YYYY Date
DInxtmt
Service information: Next
maintenance
string DD.MM.YYYY Date
13.1.14 Error codes (sFA)
Error code Description Example
sFA 1 Method requires higher user level sWN command without prior
log on
sFA 3 Unknown variable sWN parFxdSpd +10
sFA 4 Variable value range violated sWN parTeachCycles +10
sFA A Variable is write-protected sWN mvVolumeSum +1000
sFA B Invalid command for this method sWT parFixedSpeed +10
sFA F Value range for the variable type
violated
sWN parTeachCycles -1
sFA 11 Unknown character in the telegram sWN parFixedSpeed +1y0
(Other) Please contact SICK support.