OPERATING INSTRUCTIONS| Bulkscan LMS5118014829/ZNC5/2017-06-06| SICK
Subject to change without notice
57
COMMISSIONING
Optimization
for belts with slits and gaps disabled.
Te
ach-in failed. The 7-segment display shows
Maximum
distance
Fig. 35: Optimization for slits or gaps
How to correct conveyor belt irregularities:
Activate the Optimization for belts with slits or gaps checkbox on the Teach-incong-
uration bar
Set the Maximum distance so that all invalid measurement points are outside of the
scan radius
Click Teach-in
8.2 Performing a test measurement
Use the scan view in SOPAS to verify the measured contour and the generated mea-
sured values online.
The scan view depends on the available bandwidth of the chosen connection and is not
output in real-time. For this reason not all measured values are displayed.
How to carry out a test measurement:
Start SOPAS and establish a connection to the sensor.
Log in as Authorized client.
Ensure that hazard-free operation is possible and start the full conveyor belt.
On the Operating modecongurationbar,clickMeasuring mode to start the mea-
surement.
Compare the Contour displayed and the Measured value with the value expected.
Check, in particular, whether the volume sum or mass sum measured by the sensor
corresponds to the number of volume quotas or mass quotas signaled on the digital
outputs.
Ifnecessary,correctthecongurationoftheparametersintheSystem tab
Z (see "8.3 Setting tolerances“ on page 57).
Z (see "8.4 Monitoring of the contamination degree“ on page 60).
8.3 Setting tolerances
Youcanusethetolerancestoreducetheeffectsofvibration,strongreectiononthe
bulk,dazzleandotherenvironmentalinuencesonthemeasuredvalues.
Optimization for belts with slits and gaps enabled.
Teach-in successful. The 7-segment display shows
Maximum
distance
Note