OPERATING INSTRUCTIONS | Bulkscan LMS511 8014829/ZNC5/2017-06-06 | SICK
Subject to change without notice
80
APPENDIX
13 Appendix
13.1 Telegram reference
To work with telegrams, please read the following sections:
CongurationoftheBulkscanusingtelegrams(see"7.2CongurationoftheBulk-
scan using telegrams“ on page 51).
Notation and examples (see below).
The available telegrams are divided as follows based on the structure of the software
user interface:
Logging in to the sensor/Logging out of the sensor (see "13.1.2 Logging in to the
sensor/Logging out of the sensor“ on page 82).
Savingthecongurationinthenon-volatilememory(see"13.1.3Savingthecongu-
ration in the non-volatile memory“ on page 83).
Device information (see "13.1.4 Device information“ on page 83).
Operating mode/Teach-in (see "13.1.5 Operating mode/Teach-in“ on page 83).
Measured value (see "13.1.6 Measured values“ on page 84).
Measurement (see "13.1.7 Measurement“ on page 84).
System (see "13.1.8 System“ on page 85).
Digital inputs (see "13.1.10 Digital inputs“ on page 86).
Digital outputs (see "13.1.11 Digital outputs“ on page 87).
Reference measurement (compensation function) (see "13.1.12 Reference measure-
ment (compensation function)“ on page 88).
Service data (see "13.1.13 Service data“ on page 90).
Error codes (sFA) (see "13.1.14 Error codes (sFA)“ on page 90).
13.1.1 Notation and examples
Notation
The individual telegram sections must each be separated by a space (ASCII code 32,
20 h). The Bulkscan interprets the parameters transferred as follows:
Parameters with a leading "+" or "–" are interpreted as a decimal value (ASCII nota-
tion).
Parameters without a leading "+" or "–" are interpreted as a hexadecimal value (ASCII
notation).
TheBulkscaninterpretseachparameterindividually,i.e.,thedifferentnotationscan
be mixed within a telegram.
All examples used in the following telegram lists refer to the CoLaA protocol.
Structure of the data
The data comprises a command, a variable name or a method name, as well as any
necessary parameters.
Request <STX> sMN
SetAccessMode
03 F4724744 <ETX>
Reply <STX> sAN
SetAccessMode
1 <ETX>
Frame
Method: Login to the sensor
Parameter: Authorized user
Parameter: Password
Frame
Command: Execute method