OPERATING INSTRUCTIONS | Bulkscan LMS511 8014829/ZNC5/2017-06-06 | SICK
Subject to change without notice
80
APPENDIX
13 Appendix
13.1 Telegram reference
To work with telegrams, please read the following sections:
• CongurationoftheBulkscanusingtelegrams(see"7.2CongurationoftheBulk-
scan using telegrams“ on page 51).
• Notation and examples (see below).
The available telegrams are divided as follows based on the structure of the software
user interface:
• Logging in to the sensor/Logging out of the sensor (see "13.1.2 Logging in to the
sensor/Logging out of the sensor“ on page 82).
• Savingthecongurationinthenon-volatilememory(see"13.1.3Savingthecongu-
ration in the non-volatile memory“ on page 83).
• Device information (see "13.1.4 Device information“ on page 83).
• Operating mode/Teach-in (see "13.1.5 Operating mode/Teach-in“ on page 83).
• Measured value (see "13.1.6 Measured values“ on page 84).
• Measurement (see "13.1.7 Measurement“ on page 84).
• System (see "13.1.8 System“ on page 85).
• Digital inputs (see "13.1.10 Digital inputs“ on page 86).
• Digital outputs (see "13.1.11 Digital outputs“ on page 87).
• Reference measurement (compensation function) (see "13.1.12 Reference measure-
ment (compensation function)“ on page 88).
• Service data (see "13.1.13 Service data“ on page 90).
• Error codes (sFA) (see "13.1.14 Error codes (sFA)“ on page 90).
13.1.1 Notation and examples
Notation
The individual telegram sections must each be separated by a space (ASCII code 32,
20 h). The Bulkscan interprets the parameters transferred as follows:
• Parameters with a leading "+" or "–" are interpreted as a decimal value (ASCII nota-
tion).
• Parameters without a leading "+" or "–" are interpreted as a hexadecimal value (ASCII
notation).
• TheBulkscaninterpretseachparameterindividually,i.e.,thedifferentnotationscan
be mixed within a telegram.
• All examples used in the following telegram lists refer to the CoLaA protocol.
Structure of the data
The data comprises a command, a variable name or a method name, as well as any
necessary parameters.
Request <STX> sMN
SetAccessMode
03 F4724744 <ETX>
Reply <STX> sAN
SetAccessMode
1 <ETX>
Frame
Method: Login to the sensor
Parameter: Authorized user
Parameter: Password
Frame
Command: Execute method