OPERATING INSTRUCTIONS| Bulkscan LMS5118014829/ZNC5/2017-06-06| SICK
Subject to change without notice
69
TECHNICAL DATA
Supply voltage
Sensor
Heating
19.2 V
19.2 V
24 V
24 V
28.8 V
28.8 V
Permissible residual ripple ±5%
Switch on current 2 A
Operating current
Sensor
Heating
1,3 A
1,8 A
Power consumption
Sensor
Heating
22 W
55 W
25 W
65 W
Digital inputs
Input voltage
Input resistance for HIGH
Voltage for HIGH
Voltage for LOW
Input capacity
Static input current
11 V
11 V
6 mA
2kΩ
24 V
0 V
15 nF
30 V
30 V
5 V
15 mA
Encoder inputs
Input resistance for HIGH
Voltage for HIGH
Voltage for LOW
Input capacity
Static input current
Duty cycle (Ti/T)
Input frequency
Current load
11 V
-3 V
6 mA
2kΩ
24 V
0 V
1 nF
0,5
50 mA
30 V
5 V
15 mA
100 kHz
100 mA
Digital outputs
Voltage drop load
Maximum switching current
Current limiting (after 5 ms at 25 °C)
Power-up delay
Power-down time
100 mA
Negligible
2 V
0.8 ms
140 mA
200 mA
2 ms
Mechanical data
Housing color RAL 7032 (gray)
Enclosure rating IP 67 (as per IEC 60529 Edition 2.2:2013-08)
Protection class III
Weight 3.7 kg
Dimensions B 155 mm × T 159 mm × H 185 mm
Ambient data
EMC test As per IEC 61000-6-2:2016-08,
IEC 61000-6-3:2006-07
Vibration resistance
Frequency range
Amplitude
10 Hz
5 g RMS
150 Hz
Shock resistance
Single shock
Continuous shock
IEC 60068-2-27
15 g, 11 ms
10 g, 16 ms
Operating temperature range –40 °C +60 °C