7.1
Technical data
1)
: The accuracy depends on calibration, installation conditions, flow profile, temperature and length of the
measuring distance
2)
: For operation with standard configuration (factory setting)
Measured value recording
Measured variables Flow velocity, air temperature
Measuring range –20 ... +20 m/s; infinitely variable; higher on request
Typical accuracy
1)
± 0.1 m/s
Response time 1 ... 300 s; freely selectable
Displays
LC display For measured variables, warning and malfunction messages
LED Voltage supply OK, malfunction, maintenance request
Installation
Measuring distance
Transducer - transducer
FLSE200-M and FLSE200-HM 5 ... 25 m
FLSE200-H 5 ... 40 m
Installation angle Up to 10 m measuring distance 45°, for longer measuring distances 60°
Air temperature -40 ... +60 °C
Moisture < 100%
Total cable length between
FLSE200 and MCU.
Max. 1000 m
2)
Output signals
Analog output 0/2/4 ... 22 mA, max. load 750 ; resolution 0.01 mA
further analog outputs with I/O modules (option)
Digital outputs 5 potential-free outputs (NC contacts) for status signals operation/fault, maintenance, control
cycle, maintenance requirement, limit value; contact load 48 V, 1 A;
further relay outputs with I/O modules (option)
Input signals
Analog input 2 inputs 0 ... 20 mA (standard, without electrical isolation); resolution 0.01 mA;
further analog inputs with I/O modules (option)
Digital inputs 4 potential-free contacts for connection of maintenance switch, activation of check cycle;
further digital inputs with I/O modules (option)
Communication interfaces
USB 1.1, RS 232 (on terminals) For measured value inquiry, configuration and software update via PC/laptop with operating
program
RS485 For connection of sender/receiver units
Option Interface module Optional PROFIBUS (RS485), MODBUS (RS485, Ethernet), COLA-B (Ethernet)
Power supply
Operating voltage 90 ... 250 V AC; 50/60 Hz
Power consumption Approx. 20 W
Ambient conditions
Temperature range -40 ... +60 °C
Storage temperature -40 ... +70 °C
Protection class FLSE200: IP66, MCU: IP 65