Available instances
•
ID1
13.5.2.7 TCP/IP object (0xF5)
Object class
Attribute ID Access rule Name Data type
Dec Hex
1 0x01 Get Revision UINT
2 0x02 Get Max Instance UINT
Services
•
G
et_Attribute_Single
Object instance
Attribute ID Access rule Name Data type
Dec Hex
1 0x01 Get Status DWORD
2 0x02 Get Configuration Capabil‐
it
y
DWORD
3 0x03 Get/Set Configuration Control DWORD
4 0x04 Get Physical Link Object STRUCT
5 0x05 Get/Set Interface Configura‐
t
ion
STRUCT
6 0x06 Get/Set Host Name STRING
7 0x07 Get Safety Network Num‐
ber
6 octets
10 0x0A Get/Set SelectACD BOOL
11 0x0B Get/Set LastConflictDetected STRUCT
13 0x0D Get/Set Encapsulation Inactiv‐
it
y Timeout
UINT
Services
•
G
et_Attributes_All
•
Get_Attribute_Single
•
Set_Attribute_Single
Available instances
•
ID1
13.5.2.8 Ethernet link object (0xF6)
Object class
Attribute ID Access rule Name Data type
Dec Hex
1 0x01 Get Revision UINT
2 0x02 Get Max Instance UINT
3 0x03 Get Number of Instances UINT
Services
•
G
et_Attribute_Single
13 T
ECHNICAL DATA
136
O P E R A T I N G I N S T R U C T I O N S | nanoScan3 – EtherNet/IP™ 8027909/2023-02-22 | SICK
Subject to change without notice