Open field editor settings
Field display
S
afety Designer displays the field types in different colors.
Table 15: Colors of the field types
Protective field Warning field Reference contour field and
c
ontour detection field
Red Yellow Turquoise
Create fields and field sets
T
able 16: Buttons for field sets
Add field set
Add field to field set
Duplicate field set
Delete field or field set
Hide or show field sets and fields
Manage field set templates
Importing field sets and fields
Exporting field sets and fields
Name
Y
ou can assign a unique name for each field set.
Name and F
ield type
You can assign a unique name and select a field type for each field.
Multiple sampling and Ob
ject resolution
At first, the object resolution and multiple sampling configured for the monitoring plane
apply for all fields. If necessary, you can make changes to each individually at a later
date.
Tolerance band
A c
ontour has a positive and a negative tolerance band. If the safety laser scanner does
not detect the contour within the tolerance band, the field switches to the OFF state.
•
Positive tolerance (far): The tolerance away from the safety laser scanner
•
Negative tolerance (near): The tolerance toward the safety laser scanner
7 C
ONFIGURATION
74
O P E R A T I N G I N S T R U C T I O N S | nanoScan3 – EtherNet/IP™ 8027909/2023-02-22 | SICK
Subject to change without notice