SURPASS hiD 6615 S223/S323 R1.5
A50010-Y3-C150-2-7619 115
If you want to delete a configured alarm severity, use the following command.
Command Mode Description
no snmp alarm-severity fan-fail
no snmp alarm-severity cold-start
no snmp alarm-severity broadcast-over
no snmp alarm-severity cpu-load-over
no snmp alarm-severity dhcp-lease
no snmp alarm-severity dhcp-illegal
no snmp alarm-severity fan-remove
no snmp alarm-severity ipconflict
no snmp alarm-severity memory-over
no snmp alarm-severity mfgd-block
no snmp alarm-severity port-link-down
no snmp alarm-severity port-remove
no snmp alarm-severity port-thread-over
no snmp alarm-severity power-fail
no snmp alarm-severity power-remove
no snmp alarm-severity rmon-alarm-rising
no snmp alarm-severity rmon-alarm-falling
no snmp alarm-severity system-restart
no snmp alarm-severity module-remove
no snmp alarm-severity temperature-high
Global Deletes a configured alarm severity.
7.1.9.5 ADVA Alarm Severity
To configure a severity of alarms for ADVA status, use the following command.
Command Mode Description
snmp alarm-severity adva-fan-fail {critical |
major | minor | warning | intermediate}
Sends alarm notification with the sever-
ity when ADVA informs fan-fail.
snmp alarm-severity adva-if-misconfig {critical
|
major | minor | warning | intermediate}
Sends alarm notification with the sever-
ity when ADVA informs there’s any mis-
configuration.
snmp alarm-severity adva-if-opt-thres {critical |
major | minor | warning | intermediate}
Sends alarm notification with the sever-
ity when ADVA informs traffic is over
threshold on optical interface.
snmp alarm-severity adva-if-rcv-fail {critical |
major | minor | warning | intermediate}
Sends alarm notification with the sever-
ity when ADVA informs to fail to receive
the packets.
snmp alarm-severity adva-if-sfp-mismatch
{
critical | major | minor | warning | intermedi-
ate
}
Global
Sends alarm notification with the sever-
ity when ADVA informs SFP module is
mismatched.

Table of Contents