EasyManua.ls Logo

Siemens S223 - Fig. 8.16 Convergence of 802.1 D Network; Fig. 8.17 Network Convergence of 802.1 W (1)

Siemens S223
381 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual UMN:CLI
SURPASS hiD 6615 S223/S323 R1.5
A50010-Y3-C150-2-7619 207
Switch B Switch C
BPDU Flow
ROOT
Switch D
1. New link created
2. Transmit BPDU
at listening state
3. Block to
prevent loop
Switch A
Fig. 8.16 Convergence of 802.1d Network
This is very an epochal way of preventing a loop. The matter is that communication is
disconnected during two times of BPDU Forward-delay till a port connected to switch D
and SWITCH C is blocked. Then, right after the connection, it is possible to transmit
BPDU although packet cannot be transmitted between switch A and root.
Switch B Switch C
ROOT
Switch D
1. New link created
2. Negotiate between
Switch A and ROOT
(Traffic Blocking)
Switch A
Fig. 8.17 Network Convergence of 802.1w (1)

Table of Contents