4.5.1 802.1x Authentication
4.5.1.1 Enabling 802.1x
To configure 802.1x, the user should enable 802.1x daemon first. In order to enable
802.1x daemon, use the following command.
Command Mode Description
dot1x system-auth-control Enables 802.1x daemon.
no dot1x system-auth-control
Global
Disables 802.1x daemon.
4.5.1.2 Configuring RADIUS Server
As RADIUS server is registered in authenticator, authenticator also can be registered in
RADIUS server.
Here, authenticator and RADIUS server need extra data authenticating each other be-
sides they register each other’s IP address. The data is the key and should be the same
value for each other. For the key value, every kinds of character can be used except for
the space or special character.
[Suppliant] [Authenticator] [Authentication Server]
RADIUS
Server
RADIUS Servers
A : 10.1.1.1
B : 20.1.1.1
C : 30.1.1.1
:
J : 100.1.1.1
Response
Authentication request
in order
Designate as default
RADIUS server
Fig. 4.2 Multiple Authentication Servers
If you register in several servers, the authentication server starts form RADIUS server
registered as first one, then requests the second RADIUS server in case there’s no re-
sponse. According to the order of registering the authentication request, the authentica-
tion request is tried and the server which responds to it becomes the default server from
the point of response time.