To enable/disable self loop detection, use the following command.
Command Mode Description
self-loop-detect {enable | dis-
able
}
Bridge Enables/disables self loop detection function.
To display a configuration for BPDU, use the following command.
Command Mode Description
show self-loop-detect
Shows status of self loop detection and a port where
loop is happed.
show self-loop-detect {all |
PORTS}
Enable
Global
Bridge
Shows self loop detection status on specified ports:
all: all the ports
PORTS: selected port
8.3.9.8 Displaying BPDU Configuration
To display the configuration for BPDU, use the following command.
Command Mode Description
show stp mst MSTID-RANGE {all
| PORTS} [
detail]
show stp mst MSTID-RANGE all
[
detail]
show stp mst MSTID-RANGE
PORTS [
detail]
Shows a configuration for BPDU for STP, RSTP and
MSTP.
show stp pvst VLAN-RANGE
[
all | PORTS] [detail]
Enable
Global
Bridge
Shows a configuration for BPDU for PVSTP and
PVRSTP.