To delete and modify the configuration, use the following command.
Command Mode Description
mirror disable Deactivate monitoring.
mirror del PORTS [ingress |
egress]
Bridge
Delete a port from the mirrored ports.
Step 5
To disable monitoring function, use the following command.
Command Mode Description
no mirror monitor Bridge Disable port mirroring function.
The following is an example of configuring port mirroring with a port.
Step 1
Connect a motoring PC to the monitor port of the switch.
Step 2
Enable mirroring function.
SWITCH(bridge)# mirror enable
SWITCH(bridge)#
Step 3
Configure the monitor port 1 and mirroring port 2, 3, 4 and 5.
SWITCH(bridge)# mirror monitor 1
SWITCH(bridge)# mirror add 2
SWITCH(bridge)# mirror add 3-5
SWITCH(bridge)#
Step 4
Check the configuration.
SWITCH(bridge)# show mirror
Mirroring enabled
Monitor port =
-----------------------------------
| 1
|123456789012
-----------------------------------
Ingress Mirrored Ports|............
Egress Mirrored Ports|............
SWITCH(bridge)#