6 System Environment
6.1 Environment Configuration
You can configure a system environment of the hiD 6615 S223/S323 with the following
items:
Host Name
Time and Date
Time Zone
Network Time Protocol
Simple Network Time Protocol (SNTP)
Terminal Configuration
Login Banner
DNS Server
Fan Operation
Disabling Daemon Operation
System Threshold
6.1.1 Host Name
Host name displayed on prompt is necessary to distinguish each device connected to
network.
To set a new host name, use the following command.
Command Mode Description
hostname NAME Creates a host name of the switch, enter the name.
no hostname [NAME]
Global
Deletes a configured host name, enter the name.
To see a new host name, use the following command.
Command Mode Description
show running-config hostname Global Shows the host name.
The following is an example of changing hostname to “hiD6615”
SWITCH(config)# hostname hiD6615
hiD6615(config)#