EasyManua.ls Logo

Siemens S223 - Jumbo-Frame Capacity

Siemens S223
381 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
User Manual UMN:CLI
SURPASS hiD 6615 S223/S323 R1.5
A50010-Y3-C150-2-7619 275
Command Mode Description
no storm-control {broadcast |
multicast | dlf} [PORTS]
Bridge
Disables broadcast, multicast, or DLF storm control
respectively.
To display a configuration of storm control, use the following command.
Command Mode Description
show storm-control
Enable
Global
Bridge
Displays storm control configuration.
8.12 Jumbo-frame Capacity
The packet range that can be capable to accept is from 64 bytes to 1518 bytes. Therefore,
packets not between these ranges will not be taken. However, the hiD 6615 S223/S323
can accept Jumbo-frame larger than 1518 bytes through user’s configuration.
To configure to accept Jumbo-frame larger than 1518 bytes, use the following command.
Command Mode Description
jumbo-frame PORTS <1518-
9000>
Bridge
Configures to accept jumbo-frame between specified
ranges.
1518-9000: Max packet length
To disable configuration to accept Jumbo-frame, use the following command.
Command Mode Description
no jumbo-frame PORTS Bridge
Disables configuration to accept jumbo-frame on speci-
fied port.
To display the configuration of Jumbo-frame, use the following command.
Command Mode Description
show jumbo-frame
Enable
Global
Bridge
Shows a configuration of jumbo frame.
Sample Configuration
The following is an example of configuration to accept Jumbo-frame under 2200 bytes in
port 1~10.
SWITCH# configure terminal
SWITCH(config)# bridge
SWITCH(bridge)# jumbo-frame 1-10 2200
SWITCH(bridge)# show jumbo-frame
Name : Current/Default
port01 : 2200/ 1518

Table of Contents