UMN:CLI User Manual
SURPASS hiD 6615 S223/S323 R1.5
136 A50010-Y3-C150-2-7619
Syslog Output Level with a Priority
To set a user-defined syslog output level with a priority, use the following command.
Command Mode Description
syslog output priority {auth | authpriv | cron |
daemon | kern | local1 | local2 | local3 | local4 |
local5 | local6 | local7 | lpr | mail | news | sys-
log
| user | uucp} {emerg | alert | crit | err |
warning | notice | info} console
Generates a user-defined syslog mes-
sage with a priority and forwards it to
the console.
syslog output priority {auth | authpriv | cron |
daemon | kern | local1 | local2 | local3 | local4 |
local5 | local6 | local7 | lpr | mail | news | sys-
log
| user | uucp} {emerg | alert | crit | err |
warning | notice | info} local {volatile | non-
volatile
}
Generates a user-defined syslog mes-
sage with a priority in the system mem-
ory.
volatile: deletes a syslog message after
restart.
non-volatile: reserves a syslog mes-
sage.
syslog output priority {auth | authpriv | cron |
daemon | kern | local1 | local2 | local3 | local4 |
local5 | local6 | local7 | lpr | mail | news | sys-
log
| user | uucp} {emerg | alert | crit | err |
warning | notice | info} remote IP-ADDRESS
Global
Generates a user-defined syslog mes-
sage with a priority and forwards it to a
remote host.
To disable a user-defined syslog output level, use the following command.
Command Mode Description
no syslog output priority {auth | authpriv | cron
|
daemon | kern | local1 | local2 | local3 | local4
|
local5 | local6 | local7 | lpr | mail | news | sys-
log
| user | uucp} {emerg | alert | crit | err |
warning | notice | info} console
no syslog output priority {auth | authpriv | cron
|
daemon | kern | local1 | local2 | local3 | local4
|
local5 | local6 | local7 | lpr | mail | news | sys-
log
| user | uucp} {emerg | alert | crit | err |
warning | notice | info} local {volatile | non-
volatile
}
no syslog output priority {auth | authpriv | cron
|
daemon | kern | local1 | local2 | local3 | local4
|
local5 | local6 | local7 | lpr | mail | news | sys-
log
| user | uucp} {emerg | alert | crit | err |
warning | notice | info} remote IP-ADDRESS
Global
Deletes a specified user-defined syslog
output level with a priority.
The order of priority is emergency > alert > critical > error > warning > notice > info >
debug. If you set a specific level of syslog output, you will receive only a syslog message
for selected level or higher. If you want receive a syslog message for all the levels, you
need to set the level to debug.