6.4.10 LLDP
Status of the neighborhood table
This page shows the current content of the neighborhood table. This table stores the
information that the LLDP agent has received from connected devices.
You set the interfaces via which the LLDP agent receives or sends information in the following
section: "Layer 2 > LLDP".
Description
The table contains the following columns:
System Name
System name of the connected device.
Device ID
Device ID of the connected device. The device ID corresponds to the device name assigned
via PST (STEP 7). If no device name is assigned, the MAC address of the device is
displayed.
Local Interface
Port at which the device received the information
Hold Time
An entry remains stored on the device for the time specified here. If the IE switch does not
receive any new information from the connected device during this time, the entry is deleted.
Configuring with Web Based Management
6.4 "Information" menu
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
108 Configuration Manual, 11/2019, C79000-G8976-C485-03

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W1780 and is the answer not in the manual?

Siemens SCALANCE W1780 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W1780
CategoryWireless Access Point
LanguageEnglish

Related product manuals