3. Select the check box in the required row "Trap".
4. Click the "Set Values" button.
Deleting a trap entry
1. Enable "Select" in the row to be deleted.
2. Click the "Delete" button. The entry is deleted.
6.5.11.3 v3 Groups
Security settings and assigning permissions
SNMP version 3 allows permissions to be assigned, authentication, and encryption at protocol
level. The security level and read/write permissions are assigned according to groups. The
settings automatically apply to every member of a group.
Description
The page contains the following boxes:
Group Name
Enter the name of the group. The maximum length is 32 characters.
Security Level
Select the security level (authentication, encryption) valid for the selected group. The
available options are as follows:
No Auth/no Priv
No authentication enabled/no encryption enabled.
Auth/no Priv
Authentication enabled/no encryption enabled.
Auth/Priv
Authentication enabled/encryption enabled.
Configuring with Web Based Management
6.5 "System" menu
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03 185