NTP Server Port
Enter the port of the NTP server.
The following ports are possible:
123 (standard port)
1025 to 36564
Poll Interval[s]
In this field, enter the interval between two time queries (query interval) in seconds. Possible
values are 64 to 1024 seconds.
Procedure
1. Click the "NTP Client" check box to enable the automatic time setting using NTP.
2. Enter the necessary values in the following boxes:
Time zone
IP address or FQDN of the NTP server
NTP Server Port
Query interval
3. Click the "Set Values" button.
6.5.12.6 SIMATIC Time Client
Time setting via SIMATIC time client
Note
To avoid time jumps, make sure that there is only one time server in the network.
Configuring with Web Based Management
6.5 "System" menu
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03 201