7. Enable the SMTP server entry.
8. Click the "Set Values" button.
Note
Depending on the properties and configuration of the SMTP server, it may be necessary to
adapt the "Sender E-Mail Address" input for the e-mails. Check with the administrator of the
SMTP server.
Testing the configuration of the SMTP server
1. Configure recipients
Click the "Recipient" tab.
Select the desired SMTP server under "SMTP server".
Enter the desired address under "E-mail address of the SMTP recipient".
Click the "Create" button. A new entry is generated in the table. The setting "Send" is
activated by default.
2. Send test e-mail
Click the "General" tab.
Click the "Test" button next to the SMTP server entry. The device sends to every
configured recipient
Check the test result. If sending was not successful, the message contains possible
causes.
6.5.9.2 Recipient
On this page, you specify who receives an e-mail when an event occurs.
Configuring with Web Based Management
6.5 "System" menu
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
172 Configuration Manual, 11/2019, C79000-G8976-C485-03

Table of Contents