Requirements for sending log entries:
The Syslog function is enabled on the device.
The Syslog function is enabled for the relevant event.
There is a Syslog server in your network that receives the log entries. (Since this is a UDP
connection, there is no acknowledgment to the sender)
The IP address or the FQDN (Fully Qualified Domain Name) of the Syslog server is entered
in the device.
Description
The page contains the following boxes:
Syslog Client
Enable or disable the Syslog function.
Syslog Server Address
Enter the IP address, the FQDN (Fully Qualified Domain Name) or the host name of the
Syslog server.
This table contains the following columns
Select
Select the row you want to delete.
Syslog Server Address
Shows the IP address, the FQDN (Fully Qualified Domain Name) or the host name of the
Syslog server.
Server Port
Enter the port of the Syslog server being used.
Procedure
Enabling function
1. Select the "Syslog Client" check box.
2. Click the "Set Values" button.
Configuring with Web Based Management
6.5 "System" menu
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
204 Configuration Manual, 11/2019, C79000-G8976-C485-03

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W1780 and is the answer not in the manual?

Siemens SCALANCE W1780 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W1780
CategoryWireless Access Point
LanguageEnglish

Related product manuals