EasyManuals Logo

Siemens SCALANCE W1780 User Manual

Siemens SCALANCE W1780
368 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #244 background imageLoading...
Page #244 background image
The second graphic contains the following elements:
Bar (left)
In the bar on the left-hand side the transfer attempts and the data rate of the client / access
point are displayed according to the color scheme.
Color scheme
The range > -35 dBm (blue) is the overmodulation range, in other words the WLAN signal
is too strong and is received overmodulated. As of approximately -60 dBm (yellow) the
WLAN signal is weaker. The individual colors are described again under the graphic.
x axis
The x axis shows the course of the measurement in random samples and seconds.
Measurement data
Client
The measurement data shows the transfer attempts according to the color scheme
shown. The transfer attempts are shown as a bar. The data rate of the sent data packets
is represented as a line. If the client changes access points during a measurement
(roaming) or reconnects, this is displayed by a vertical black line.
Access point
The measurement data shows the transfer attempts according to the color scheme
shown. The transfer attempts are shown as a bar. The data rate of the sent data packets
is represented as a line.
If the client changes access points during a measurement (roaming) or reconnects, this
is displayed by a vertical black line. If the access point does not support the setting
"Bidirectional Recording" no data is displayed.
Beside the graphics the following values are displayed:
Status
Shows whether or not the signal recorder is recording values.
Current Sample
The number of the current measurement
CL RX-Signal [dBm] / AP RX-Signal [dBm]
The effective user signal of the client / access point in dBm
CL NF [dBm] / AP NF [dBm]
The background noise of the client / access point in dBm
CL Retries [%] / AP Retries [%]
The transfer repetitions of the client / access point as a percentage.
CL RSSI / AP RSSI
The raw value of the RSSI (Received Signal Strength Indication) of the client / access point
CL TX-Rate [Mbps] / AP TX-Rate [Mbps]
The average data rate of the sent data packets during the current random test
CL M-Signal [dBm]
If the client has an iPCF-MC connection, the user signal of the management channel is
displayed.
Roaming Counter
The roaming counter shows how often the client has changed access points during the
recording. After 4,294,967,295 changes, the counter is reset.
Configuring with Web Based Management
6.6 "Interfaces" menu
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
244 Configuration Manual, 11/2019, C79000-G8976-C485-03

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W1780 and is the answer not in the manual?

Siemens SCALANCE W1780 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W1780
CategoryWireless Access Point
LanguageEnglish

Related product manuals