Operative Channel
The current channel or the channel on which the client is connected to the access point
AP System Name
The system name of the access point
BSSID
The BSSID (Basic Service Set Identification) of the access point.
Connected Stations
Number of clients connected to the access point over the same VAP interface.
Bidirectional Status
Shows whether the data of the access point are also being recorded.
The table below the graphic contains the following columns:
Radio
Shows the WLAN interface to which the information applies. Since a client has a WLAN
interface, there is only ever one row for "WLAN 1" in this table.
Interval [ms]
Specify the time interval between acquiring two measured values in milliseconds. The first
measured value is displayed only after the set time interval has elapsed.
Samples
Specify how many measurements should be made.
Endless
If you enable the option check mark, the number of measurements is unlimited The
"Samples" box is grayed out . The signal recorder runs until it is stopped manually or the
device is reconfigured.
You can only select this option starting at a time interval ≥ 100 milliseconds.
If the recording contains more than 10000 measurements, the last 10000 measurements
are listed in the csv file and the PDF file.
Bidirectional Recording
If you enable the setting the values of the access point as of a time interval of ≥ 10
milliseconds.
The setting is supported by access points with the following versions: SCALANCE W700
11n > V6.1 and SCALANCE W1700 11ac > V1.0.
Start
Click the button in this column to start recording the wanted signal.
Note
If you start a new recording, the previous recording will be overwritten.
If the recording has lasted less than 10 minutes and has not yet been completed (e.g.
due to a restart or power down), the measured values are deleted.
The signal recorder saves the recorded data automatically every 10 minutes. Following a
restart, the recording contains all the values up to the last save action.
Configuring with Web Based Management
6.6 "Interfaces" menu
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
Configuration Manual, 11/2019, C79000-G8976-C485-03 245

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W1780 and is the answer not in the manual?

Siemens SCALANCE W1780 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W1780
CategoryWireless Access Point
LanguageEnglish

Related product manuals