The PDF file contains a graphic representation of the course of the effective user data signal in
dBm and the course of the data rate in Mbps. In terms of color, the graphic corresponds to the
appearance in the Web Based Management. If the client changes the access point (roaming)
during the measurement, this is indicated by vertical black bars with a black square at the tip.
The display is divided into two areas:
Client
Represents the measurement of the client.
Access point
Displays the measurement of the access point with which the client is currently connected.
This requires that the setting "Bidirectional Recording" is enabled. The setting is supported
by access points with the following versions: SCALANCE W700 11n > V6.1 and
SCALANCE W1700 11ac > V1.0. The access point sends its data to a maximum of 3 clients
on which signal recorders are running. The access point data is not displayed on other
clients.
If the client has an iPCF-MC connection, the user signal of the management channel is shown
with an additional black line.
Below the graphic, the configuration data of the client is displayed.