Shared Secret
Enter the password of the RADIUS server.
For the password, ASCII code 0x20 to 0x7e is used.
Shared Secret Conf
Confirm the password.
Max. Retransmissions
Enter the maximum number of connection attempts.
Primary Server
Specify whether or not this server is the primary server.
Yes: Primary server
No: Backup server.
State
With this check box, you can enable or disable the RADIUS server
Procedure
Entering a new server
To display a new server, follow the steps below:
1. In the relevant row, enter the following data in the input boxes:
IP address or FQDN of the RADIUS server
Port number of the input port
Password
Confirmation of the password
Maximum number of transmission retries
Primary server
2. Click the "Set Values" button.
Modifying servers
1. In the relevant row, enter the following data in the input boxes:
IP address or FQDN of the RADIUS server
Port number of the input port
Password
Confirmation of the password
Maximum number of transmission retries
Primary server
2. Click the "Set Values" button.
Repeat this procedure for every server whose entry you want to modify.
Configuring with Web Based Management
6.10 "Security" menu
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
318 Configuration Manual, 11/2019, C79000-G8976-C485-03