Messages about MSTP
Messages Description
You enable or disable the "Spanning Tree" event in "System > Events"
Spanning Tree: topology change detected. The topology of the network has changed; the network will be reorgan‐
ized.
Spanning Tree: new root bridge xx:xx:xx:xx:xx:xx
detected.
The topology of the network has changed; there is a new root bridge with
MAC address xx:xx:xx:xx:xx:xx in the network.
Messages about security
Messages Description
RADIUS: Access accepted / rejected for client
<MAC>.
The authentication of the client was successful or not successful.
Messages about message system
Messages Description
Syslog-Server not reachable! The configured Syslog server is not accessible.
Unable to send messages to syslog server.
Please check syslog socket configuration.
The syslog server configuration is incomplete.
Unable to send e-mail(s) because of IP connec‐
tion failure.
Sending of e-mail(s) failed. SMTP server cannot be reached (e.g. network
connection interrupted).
Unable to send e-mail(s) because of SMTP au‐
thentication failure.
Sending of e-mail(s) failed. Authentication of the client on the SMTP
server incorrect.
Unable to send e-mail(s) because SMTP mes‐
sage transfer failed.
Sending of e-mail(s) failed. SMTP server can be reached, configuration
incomplete or contains errors (e.g. receiver e-mail address wrong / does
not exist).
SNMP: Authentification failure. Authentication of an SNMP client failed; access not possible (e.g.
SNMPv1/v2 read-only configured or Read Community String incorrectly
configured).
IP communication is possible. Remote logging
activated.
IP communication is possible. Remote logging is activated.
IP communication is not possible. Remote log‐
ging deactivated. Please check IP configuration
and network connectivity.
IP communication is not possible. Remote logging is deactivated. Check
whether or not the device has an IP address.
Messages during system startup (PLUG)
Alarm Description
Startup configuration: Internal storage
PLUG: Not present There is no PLUG inserted.
Startup configuration: Internal storage
PLUG: Missing
PLUG: License missing
There is no PLUG inserted. Functions are configured on the device for
which a
PLUG License (CLP) is required.
Appendix D
D.1 Messages in the event log
SCALANCE W1780/W1740 according to IEEE 802.11ac Web Based Management
352 Configuration Manual, 11/2019, C79000-G8976-C485-03

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W1780 and is the answer not in the manual?

Siemens SCALANCE W1780 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W1780
CategoryWireless Access Point
LanguageEnglish

Related product manuals