Terminal information and wiring rules
Table 5-1 Terminal information for SIDOOR ATD4xxW
Interface Name Terminal Tool Solid con‐
ductor
Stranded
conductor
AWG Nm Strip‐
ping in‐
sulation
X3 Input power sup‐
ply
WAGO:
721-103/026-045
SZS
0.6X3.5
1x 1.5-2.5
mm
2
1x 1.5-2.5
mm
2
15 - 12 - 8-9 mm
X4 DC output PHOENIX:
1792757
SZS
0.6X3.5
1x 0.2-2.5
mm
2
1x 0.2-2.5
mm
2
30 - 12 0.5 - 0.6 7 mm
X5 Input 0 PHOENIX:
1792249
Only with
ATD420W,
ATD430W
SZS
0.6X3.5
1x 0.2-2.5
mm
2
1x 0.2-2.5
mm
2
30 - 12 0.5 - 0.6 7 mm
PHOENIX:
1779987
for ATD401W
SZS
0.6X3.5
1x 0.2-2.5
mm
2
1x 0.2-2.5
mm
2
30 - 12 0.5 - 0.6 7 mm
X6 Input 1…4 PHOENIX:
1792799
SZS
0.6X3.5
1x 0.2-2.5
mm
2
1x 0.2-2.5
mm
2
30 - 12 0.5 - 0.6 7 mm
X7 Motor plug PHOENIX:
1757077
SZS
0.6x3.5
1x 0.2-2.5
mm
2
1x 0.2-2.5
mm
2
30 - 12 0.5 - 0.6 7 mm
X11, X12,
X13
Relay module Re‐
lay outputs
1
*
PHOENIX:
1757022
SZS
0.6X3.5
1x 0.2 – 2.5
mm
2
1x 0.25 – 2.5
mm
2
30 - 12 0.5 - 0.6 7 mm
X100 PROFIBUS/
PROFINET module
relay outputs
1
**
PHOENIX:
1803594
SZS
0.4X2.5
1x 0.14 –
1.5 mm
2
1x 0.14 – 1.5
mm
2
30 –
14
0.22 -
0.25
7 mm
1
Only for modules with the corresponding module
* Only with ATD401W
** Only ATD420W, ATD430W
Controllers
5.3 Wiring instructions
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA 131