DTErrAND2 signal
Firmware version V1.12 or higher:
The DTErrAND2 signal is located in the upper byte of the TZW2 (bit 7). It has a binary structure.
Table A-35 DTErrAND2 signal
DTErrAND0 sig‐
nal value
Name Description
0 No discrepancy er‐
ror AND2
No discrepancy error was detected at function block AND2.
1 Discrepancy error
AND2
A discrepancy error was detected at function block AND2.
You can 󹪝nd more information on the DTErrAND2 signal and the corresponding function in the
section Discrepancy analysis blocks (Page 99).
Op signal
As of 󹪝rmware version V1.14:
The Op signal (operable) is located in the upper byte of the TZW2 (Bit 11). It has a binary
structure.
The readiness for operation of the controller is signaled with this signal. The "Not ready to run"
status is signaled in the following states:
During the storage of parameter values after a parameter change.
Table A-36 Op signal
Op signal value Name Description
0 Not ready to run Drive command can currently not
be executed.
1 Ready for operation Drive command can be executed.
A.1.2.9 TZW3, TZW4, TZW5 - Technology status words 3, 4, 5
The values monitored in the technology status words TZW3, TZW4 and TZW5 can be set via the
parameters p4700, p4701 and p4702.
Table A-37 Value setting for TZW3, TZW4, TZW5
Parame‐
ter
Value range Default val‐
ue
Description
p4700 0 … 10 0 Value selection for TZW3 (see following tables)
p4701 0 … 10 1 Value selection for TZW4 (see following tables)
p4702 0 … 10 2 Value selection for TZW5 (see following tables)
Appendices
A.1 Structure of user data/process data
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA 327