The SIDOOR controller supports parameter numbers in the range of 0 to 65535. The exact
assignment of the parameter number is described in the section Parameter assignment
(Page 186).
A.1.1.5 Parameter description (PBE)
The notation of the parameter description states the element number of the parameter
description in the IND array subindex.
Table A-11 Elements of the parameter description
Element number Description Data type
0 Reserved
1 Designation ID 16 bit
2 Number of array elements 8 bit
3 Reserved
4 Reserved
5 Reserved
6 Reserved
7 Lower limit value 16 bit
8 Upper limit value 16 bit
9 Default value (factory setting) 16 bit
10 … 15 Reserved
The subindex 255 for transferring a complete parameter description or a complete array requires
a variable telegram length which is not currently supported.
The designation ID (element number 1) consists of the following bits:
Bit Description
0 … 7 Data type of the parameter value
8 Scaling and major attribute relevant
9 Write-protected
10 Additional text available
11 Reserved
12 Parameter di󹪜ers from factory settings
13 Parameter can only be reset
14 Parameter is an array
15 Reserved
Appendices
A.1 Structure of user data/process data
ATD4xxW for industrial applications
316 System Manual, 06/2022, A5E51901827B AA