Table 5-7 Assignment of X705
Pin Assignment Description
1 NC Not connected
2 NC Not connected
3 RS 485P RS 485 interface (receive and send signals (+))
Note: For 6GK1500-0FC10: "B" (red)
4
1)
CNTR-P Repeater direction control
5 GND Interface ground
6 P5V 5 V max. 10 mA, to be used in connector for bus network terminator only
7 NC Not connected
8 RS 485N RS 485 interface (receive and send signals (-))
Note: For 6GK1500-0FC10: "A" (green)
9 NC Not connected
Shield Shield FE - functional grounding (bus cable shield)
1)
with SIDOOR ATD420W
Connection
The wired PROFIBUS connector is connected to connection X705 and fastened by tightening the
screws.
5.5.2.3 Wiring and connecting relay outputs
Wiring
The PROFIBUS module has 2 relay outputs (closer contact).
A maximum voltage of 42.0 V (SELV) may be applied to the PROFIBUS module.
Contact rating of the relay outputs:
• DC max: 30 V DC, 500 mA
The matching 4-pole mating connector (PHOENIX MC1.5/4-ST-3.81) with the screw terminals is
delivered along with the module (plugged in).
The pin assignments are:
Controllers
5.5 Relay and eldbus interfaces
ATD4xxW for industrial applications