EasyManua.ls Logo

Siemens SIDOOR ATD4 W Series - DOOR OPEN (Command Given Via Digital Inputs)

Siemens SIDOOR ATD4 W Series
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Connection
SIDOOR ATD401W:
The "CLOSE DOOR" function is connected to "Input 3" (X6). See also section Digital input signals
(Page 132).
"Main menu → General setup → Special parameters → FBLOCK con󹪝gurationDefault input"
has to be selected in the control menu so that door commands can be issued via the digital
inputs.
Signals
Signal Meaning
1 (voltage applied) The CLOSE DOOR command is pending
0 (voltage not applied) The CLOSE DOOR command is not pending
4.1.6 DOOR OPEN (command given via digital inputs)
Description of function
The OPEN DOOR command opens the door according to the con󹪝gured travel curve as long as
the command is present. The door reaches the OPEN position at slow start speed. Then, if the
OPEN DOOR command is present, the door is held open by the torque that can be adjusted by
the parameter "Continuous torque open".
The OPEN DOOR command has priority over all other control commands.
Note
If the commands CLOSE DOOR and OPEN DOOR are present simultaneously, the door always
moves in the OPEN direction.
SIDOOR ATD420W / ATD430W
See also section Free function blocks (FBLOCK) (Page 92).
Note
As an alternative, the signal can also be evaluated via the PLC (process image).
Connection
SIDOOR ATD401W:
The "DOOR OPEN" function is connected to "Input 4" (X6). See also section Digital input signals
(Page 132).
SIDOOR functions
4.1 Basic functions
ATD4xxW for industrial applications
62 System Manual, 06/2022, A5E51901827B AA