Parameter Parameter ID Unit Prole 1* Adjustment range
ATD4xxW
Reversal ramp close/open p3678 mm/s
2
850 300 ... 1400
(V1.09): 250 ... 1400
(as of V1.10): 150 ...
1400
Idle torque open p3679 mA 1000 0 … 2500
Idle torque close p3680 mA 1000 0 … 2500
Peak torque close p3681 mA 3000 0 … 5000
Static force limit open p3682 N 75 70 … 300
Static force limit close p3683 N 75 70 … 300
Limit force end close p3684 N 75 70 … 300
Static NDG-force (reduced) p3685 N 75 70 … 300
Limit energy close p1202 J 4 0 … 100
Limit energy open p1203 J 4 0 … 100
Limit energy NDG p1204 J 4 0 … 100
* Default prole (this prole is automatically loaded at the rst commissioning)
A.2.3 SIDOOR MDG3 L / R (as of V1.12)
Firmware version V1.12 or higher:
The following parameter values depend on the output transmission and are dened by the factor
k1.
Maximum parameter values:
• Speeds: 999 mm/s
As of V1.12: Speeds: 1500 mm/s
• Acceleration ramps: 3000 mm/s
2
• The maximum force is limited to 300 N.
([LVWLQJRXWSXWWUDQVPLVVLRQUDWLR
6WDQGDUGRXWSXWWUDQVPLVVLRQUDWLR
k1
x
mm
Umd
The following parameter values depend on the maximum motor force and are dened by the
factor k2.
Maximum parameter values:
• Deceleration ramp: 3000 mm/s
2
)RUFHOLPLW
'HWHUPLQHGG\QDPLFPDVV
k2
* 1000
Appendices
A.2 Proles and adjustment ranges
ATD4xxW for industrial applications
System Manual, 06/2022, A5E51901827B AA 331