EasyManua.ls Logo

Siemens SIDOOR ATD4 W Series - Communications; Application-Specific Standards

Siemens SIDOOR ATD4 W Series
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Emission standard for residential environments
EN 61000-6-3: 2007+A1:2011
Generic standards Interference emission for residential, business and commercial areas as well
as small businesses
Note
The speci󹪝cations of DIN EN 61000-6-3 are met when the SIDOOR TRANSFORMER or SIDOOR
TRANSFORMER UL is used as a power supply component. EN 61000-6-3 is not ful󹪝lled if the
SIDOOR NT40 is used as the power supply component.
Emission standard for industrial environments
EN 61000-6-4:2007 +A1:2011
Generic standards Interference emission for industrial environments
A.4.3 Communications
The EIA 485 standard applies to physical data transfer (RS 485 interface).
USS protocol speci󹪝cation, Edition 09.94 by Walter Möller-Nehring, Siemens AG, ASI 1 D SP,
Erlangen and Wolfgang Bohrer, Siemens AG, ASI 1 D SP, Erlangen
PROFIBUS was de󹪝ned in DIN 19245 in 1991/1993, changed to EN 50170 in 1996 and has been
de󹪝ned in IEC 61158/IEC 61784 since 1999.
PROFINET DIN EN 61158 and IEC 61784-2
A.4.4 Application-speci󹪝c standards
WARNING
Compliance with these standards requires appropriate hardware, parameter
assignment, setup and veri󹪝cation.
power-operated guards
EN ISO 14120:2015 Safety of machinery – Isolating protective devices –
General requirements for the design and construction of 󹪝xed and movable guards, Type B
Standard
For EN ISO 14120:2015, particular attention must be paid to section 5.2.5.4:
Appendices
A.4 Standards, directives and laws
ATD4xxW for industrial applications
342 System Manual, 06/2022, A5E51901827B AA

Table of Contents

Related product manuals