X100.1
X100.2
X100.3
X100.4
Relay control
Table 5-8 Relay control for PROFIBUS module
Terminal Assignment Description
X100.1
X100.2
CLOSE
(closed)
The relay is additionally in󹪞uenced by the sensor con󹪝guration (parameter p4600).
For more, see also section Sensors and external sensor interface module (ATD4xxW)
(Page 166).
Sensor function test inactive
The system's internal door state "closed" is signaled via this relay (relay contact is
closed). This state is not only position-dependent. Note the following conditions:
The "closed" state can only be achieved with a drive order.
The "closed" state cannot be achieved by external pushing.
The "closed" state can be terminated by means of a drive order or external
pushing.
Sensor function test active
The "TestOUT" sensor function test signal is output.
X100.3
X100.4
OPEN
(open)
The system's internal door state "open" is signaled via this relay (relay contact is
closed).
This state essentially depends on the current door position.
The "open" state can be achieved both by means of a drive order and also by
external pushing.
The "open" state can be terminated by means of a drive order or external pushing.
Connection
The wired relay connector is connected to connection X100.
X100
Controllers
5.5 Relay and 󹪝eldbus interfaces
ATD4xxW for industrial applications
144 System Manual, 06/2022, A5E51901827B AA