Configure fieldbus
7.2 Communication via PROFINET
SINAMICS G110M Operating Instructions
126 Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
7.2
Communication via PROFINET
You can either communicate via Ethernet using the inverter, or integrate the inverter in a
PROFINET network.
The inverter as an Ethernet station (Page 334)
PROFINET IO operation (Page 127)
In PROFINET IO operation, the inverter supports the following functions:
RT
IRT
The inverter transmits the clock synchronism but does not support clock synchronism.
MRP
Media redundancy, impulsed with 200 ms
Requirement: Ring topology
MRPD
Media redundancy, impulse-free
Requirement: IRT and the ring topology created in the control
Diagnostic alarm
in accordance with the fault classes specified in the PROFIdrive profile. See Activating
diagnostics via the control (Page 129).
Device replacement without removable medium
Requirement: Topology created in the control
Shared device
only in the case of control units with fail-safe functions (see Safety function manual)