Service and maintenance
10.6 Correcting a failed firmware upgrade or downgrade
SINAMICS G110M Operating Instructions
286 Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
You have updated the inverter's firmware to an older version and have adopted your saved
settings in the inverter.
10.6
Correcting a failed firmware upgrade or downgrade
How does the inverter report a failed upgrade or downgrade?
The inverter signals a failed firmware upgrade or dow
n-
grade with a quickly flashing RDY LED and a lit up BF
LED.
Correcting a failed upgrade or downgrade
To correct a failed firmware upgrade or downgrade you can check the following:
Does the firmware version fulfill the requirements of your inverter?
For an upgrade at least V4.7.x.
For a downgrade at least V4.7.
Have you inserted the card properly?
Does the card contain the correct firmware?
Repeat the appropriate procedure.