3.2 SINAMICS G110M converter
SINAMICS G110M Operating Instructions
24 Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
3.2
SINAMICS G110M converter
Overview
The SINAMICS G110M system consists of the following components:
Terminal Housing (including the Control Module)
Power Module
Three-phase motor.
The Power Modules are designed for a specific power range and the terminal housings are
designed to work with specific motors. The terminal housing not only allows the direct
mounting onto a motor but specific cable glands and mains connectors are specified. All the
various combinations of Power Modules, terminal housings (including the Control Modules)
and Options are given in the tables below.
CAUTION
Converter has the potential to start running of a PLC power-cycle
The converter has the potential to start running after a power-cycle of the controlling PLC, if
an ON command was present prior to the power-cycle of the PLC.
It is the users responsibility to ensure that the converter runs only when it is appropriate of
the user's application.
Table 3- 1 PM240M Power Modules - 3AC, 400 V, Class A, IP66
Frame size
Rated output power (kW)
Rated output current (A)
Article number
based on High Overload (HO)
FSA
0.37
1.3
6SL3517-1BE11-3AM0
FSA
0.75
2.2
6SL3517-1BE12-3AM0
FSA
1.1
3.1
6SL3517-1BE13-3AM0
FSA
1.5
4.1
6SL3517-1BE14-3AM0
FSB
2.2
5.6
6SL3517-1BE16-3AM0
FSB
3.0
7.3
6SL3517-1BE17-7AM0
FSB
4.0
8.8
6SL3517-1BE21-0AM0