EasyManua.ls Logo

Siemens SINAMICS G110M - Characteristics of U;F Control

Siemens SINAMICS G110M
344 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Functions
8.6 Motor control
SINAMICS G110M Operating Instructions
Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
183
8.6.1.1
Characteristics of U/f control
The inverter has different V/f characteristics.
The voltage boost of the characteristic optimizes the speed control at low speeds
With the flux current control (FCC), the inverter compensates for the voltage drop in the stator
resistor of the motor
Figure 8-18 Characteristics of U/f control
The inverter increases its output voltage to the maximum possible output voltage. The
maximum possible output voltage of the inverter depends on the line voltage.
When the maximum output voltage is reached, the inverter only increases the output
frequency. At this point, the motor enters the field weakening range: At constant torque, the
slip decreases quadratically as the speed increases.