Technical data
12.2 Performance ratings Power Module
SINAMICS G110M Operating Instructions
304 Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
Performance ratings Power Module
SINAMICS PM240M performance ratings
Table 12- 2 Power Module performance ratings
Line operating voltage &
power ranges
3 AC 380 V (- 10%) … 480 V (+ 10%)
High Overload: 0.37 kW … 4.0 kW (0.5 hp … 5.0 hp)
Overload capability (HO)
2 x Nominal output current for 3 seconds followed by 1.5 x Nominal output
current for 57 seconds every 300 seconds (averages as 110%).
For 4 kW variant:
1.6 x Nominal output current for 3 seconds followed by 1.5 x Nominal
output current for 57 seconds every 300 seconds (averages as 110%).
Less than rated input current
4 kHz (standard); 4 kHz … 16 kHz (in 2 kHz steps)
Electromagnetic compat-
Internal Class A filters according to EN 55011
IP65/IP66 (when Power Module and Control Unit is fully assembled).
CU: -10 °C … +55 °C (14 °F … 131 °F) - High Overload (HO)
-40 °C … +70 °C (-40 °F … 158 °F)
< 95% RH - non-condensing
Up to 1000 m (3280 ft) above sea level without derating
Protection features Undervoltage, Overvoltage, Overload, Ground faults, Short circuit, Stall
prevention, Motor blocking protection, Motor overtemperature, Power
Module overtemperature, Parameter interlock
Standards UL, cUL, CE, C-tick
CE mark Conformity with EC Low Voltage Directive 73/23/EEC and filtered ver-
sions also Electromagnetic Compatibility Directive 89/336/EEC
180 V DC (400 V half-wave rectified) 1A maximum