Appendix
A.2 Star-delta motor connection
SINAMICS G110M Operating Instructions
312 Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
Function
SINAMICS
G120
G120D
11 The sign of the system deviation for the additional, free tech-
nology controller can be switched over.
A new parameter defines the sign of the system deviation
matching the particular application, e.g. for cooling or heating
applications.
- - - - - - - -
12 Line contactor control using a digital output of the inverter to
save energy when the motor is switched off
-
13 Fast flying restart for PM330 Power Modules:
The "Flying restart" function does not have to wait for the motor
demagnetization time, and identifies the motor speed without
requiring a search operation.
- - - - - - - -
14 Load torque monitoring extended to include the following func-
tions:
Protection against blocking, leakage and dry running opera-
tion in pump applications
Protection against blocking and broken belts in fan applica-
tions
- - - - -
15
Automatic switchover of the real time clock from daylight saving
time (summer time) to standard time (winter time).
- - - - - - - -
16 New or revised default settings of the interfaces: p0015 macros
110, 112 and 120
- - - - - - - -
17 Expansion of the temperature sensors to include DIN-Ni1000
for analog inputs AI 2 and AI 3
- - - - - - - -
18 Communication via AS-Interface.
Default setting of the communication via AS-i: p0015 macros
30, 31, 32 and 34
- - - - - - - -
19 Communication expansion via Modbus:
Adjustable parity bit, access to parameters and analog inputs
- - - - - - - -
20 Extending communication via BACnet:
Access to parameters and analog inputs
- - - - - - - -
21
The bus error LED for communication via USS and Modbus can
be switched off
- - -
1)
Operation with 1FK7 synchronous motors without encoder has already been released with firmware V4.7 for SINAMICS
G120D with CU240D-2 Control Units.
In the preface you can find references to the description of the new functions: Changes in
this manual (Page 5).
A.2
Star-delta motor connection
Depending on your application, you can operate the motor in the star or delta connection
(Y/Δ).