Configure fieldbus
7.5 Communications via AS-i
SINAMICS G110M Operating Instructions
154 Operating Instructions, 04/2015, FW V4.7.3, A5E31298649B AD
AS-i.DO3
AS-i.DO2
AS-i.DO1
AS-i.DO0
Response in the inverter
1
1
0
0
On + fixed speed 12 (factory setting: 1650 rpm)
1 1 0 1 On + fixed speed 13 (factory setting: 1800 rpm)
1
1
1
0
On + fixed speed 14 (factory setting: 1950 rpm)
1 1 1 1 Acknowledge fault or OFF2
Modified addressing - scaling factors
Table 7- 10 Scaling of the speed setpoint via AS-i.P0 … AS-i.P3
AS-i.P3
AS-i.P2
AS-i.P1
AS-i.P0
Scaling factor
Frequency (Hz)
1
1
1
1
1
50
1 1 1 0 0.9 45
1
1
0
1
0.8
40
1
1
0
0
0.7
35
1
0
1
1
0.6
30
1
0
1
0
0.5
25
1
0
0
1
0.45
22.5
1
0
0
0
0.4
20
0
1
1
1
0.35
17.5
0
1
1
0
0.3
15
0
1
0
1
0.25
12.5
0
1
0
0
0.2
10
0
0
1
1
0.15
7.5
0
0
1
0
0.1
5
0
0
0
1
0.07
3.5
0
0
0
0
0.05
2.5
Fixed speeds - Dual Slave
Table 7- 11 Fixed speeds via the motor control bits and response in the inverter
AS-i.DO2
AS-i.DO1
AS-i.DO0
Response in the inverter
0
0
0
OFF1
0
0
1
On + fixed speed 1 (factory setting: 1500 rpm)
0 1 0 On + fixed speed 2 (factory setting: -1500 rpm)
0
1
1
On + fixed speed 3 (factory setting: 300 rpm)
1
0
0
On + fixed speed 4 (factory setting: 450 rpm)
1
0
1
On + fixed speed 5 (factory setting: 600 rpm)
1
1
0
On + fixed speed 6 (factory setting: 750 rpm)
1
1
1
Acknowledge fault or OFF2